The Inspection
Home Exterior Inspection:
- Structure and Foundation
- Roof
New
Construction Home
Here is a new construction home inspected early this year.
The trimmer rafters were cut backwards and only bearing on
1" of the engineered roof trusses
- Gutters
- Down Spouts
- Exterior Walls (Brick, Siding, Paint, Etc)
- Chimneys
Disconnected Fireplace
Flue

A house fire would be the result if this wood burning
fireplace had been used. The flue was disconnected in the
chimney stack and was visible from the attic space.
The client actually had this new construction home inspected
the day after they moved in. They thought about starting a
fire on their first night; but decided to wait until it had
been inspected.
- Exterior Doors
- Exterior Windows & Screens
- Porches
- Decks
- Stoops & Railings
- Balconies
- Garage (Doors, Walls, Floor)
- Driveway
- Lot (Ground Slope Away From Foundation, Walkways, etc)
- Swimming Pool
- Outside Lighting
- Sprinkler System
Home Interior Inspection:
- Plumbing
- Heating Systems
- Cooling Systems
- Electric
- WindowsDoors Floors
Crawlspace Problems
Amateur and unprotected wiring can be a serious safety
hazard. The duct was installed right through the floor joist
with no bracing. The top of the joist shows water damage and
decay. A garden tub sat right above this area and water had
seeped through the carpet and subfloor. Batten insulation
(R-13) was laid across the top of the floor joist and sandwiched
between the the floor joist and plywood subfloor during initial
construction.
- Ceilings
- Ceiling Fixtures
- Closets
- Walls (Structure, Paint, etc.)
- Kitchen (Cabinets, Sink, Counters, Faucets, Etc.)
- Bathrooms (Cabinets, Toilet, Sink, Tub or Shower, Counters,
Faucets, Tile, etc.)
- Appliances
Crushed Dryer Vent

A recent inspection revealed this crushed, excessively
long and curvy dryer vent. While you may think a crushed dryer
vent is a minor find, think again. The Consumer Product Safety
Commission (CPSC) estimates that there are 24,000 lint related
dryer fires in the United States each year, resulting in $96,000,000
in property damages.
- Ventilation
- Basement (Foundation, Walls, Structure Evidence of Leaks,
Etc.)
- Attic (Insulation, Roof Structure, Ventilation, Etc)
- Smoke, CO2, Detectors
- Fireplace(s)
Other Services
I Offer For a Fee
-
Pool and Spa Inspections
-
Mold Assessments and Sampling
-
Lead Paint Testing
-
Indoor Air Quality Testing
I invite you to come along and watch as I inspect your home,
and you are free to ask questions at any time during your
home inspection.
Performing home
inspections, commercial property inspections, mold inspections,
pre-list inspections, 1 year warranty inspections and pool
and spa inspections in the following areas:
Myrtle Beach , North
Myrtle Beach, Surfside Beach, Pawleys Island and Litchfied,
Georgetown , Charleston, Conway, Aynor, Loris, Little River,
Longs, Marion and Florence
Call 843-458-1629
and Receive $20.00 OFF
(must mention web ad while scheduling the inspection)
Or
Click Here to Request Your Inspection Online
Standards of Practice For A South Carolina Home
Inspector
1.
Definitions and Scope
1.1. A home inspection is
a non-invasive, visual examination of a residential dwelling, performed for a
fee, which is designed to identify observed material defects within specific
components of said dwelling. Components may include any combination of
mechanical, structural, electrical, plumbing, or other essential systems or
portions of the home, as identified and agreed to by the Client and Inspector,
prior to the inspection process.
I.
A home inspection is intended to assist in the evaluation of the
overall condition of the dwelling. The inspection is based on observations of
the visible and apparent condition of the structure and its components on the
date of the inspection, and not the prediction of future conditions.
II.
A home inspection will not reveal every concern that exists
or ever could exist, but only those material defects observed on the day of the
inspection.
III.
A home inspection can include a survey and/or analysis of energy
flows and usage in a residential property if the client requests it.
1.2. A material defect is
a condition of a residential real property, or any portion of it,
that would have a significant, adverse impact on the value of the real
property, or that involves an unreasonable risk to people on the property. The
fact that a structural element, system or subsystem is near, at or beyond the
end of its normal useful life is not, by itself, a material defect.
1.3. An inspection report shall describe and
identify, in written format, the inspected systems, structures and components
of the dwelling, and shall identify material defects observed. Inspection
reports may contain recommendations regarding conditions reported or
recommendations for correction, monitoring or further evaluation by
professionals, but this is not required.
2.
Limitations, Exceptions & Exclusions
2.1. Limitations:
I.
An inspection is not technically exhaustive.
II.
An inspection will not identify concealed or latent defects.
III.
An inspection will not deal with aesthetic concerns or what could
be deemed matters of taste, cosmetic defects, etc.
IV.
An inspection will not determine the suitability of the property
for any use.
V.
An inspection does not determine the market value of the property
or its marketability.
VI.
An inspection does not determine the insurability of the
property.
VII.
An inspection does not determine the advisability or
inadvisability of the purchase of the inspected property.
VIII.
An inspection does not determine the life expectancy of the
property or any components or systems therein.
IX.
An inspection does not include items not permanently
installed.
X.
These Standards of Practice apply only to homes with four or fewer
dwelling units.
2.2. Exclusions:
I. The inspector is not
required to determine:
A. property
boundary lines or encroachments.
B. the
condition of any component or system that is not readily accessible.
C. the
service life expectancy of any component or system.
D. the
size, capacity, BTU, performance or efficiency of any component or
system.
E. the
cause or reason of any condition.
F. the cause
for the need of repair or replacement of any system or component.
G. future
conditions.
H. compliance
with codes or regulations.
I. the
presence of evidence of rodents, animals or insects.
J. the
presence of mold, mildew, fungus or toxic drywall.
K. the
presence of airborne hazards.
L. the
presence of birds.
M. the
presence of other flora or fauna.
N. the air
quality.
O. the
existence of asbestos.
P. the
existence of environmental hazards.
Q. the
existence of electromagnetic fields.
R. the
presence of hazardous materials including, but not limited to, the
presence of lead in paint.
S. any
hazardous waste conditions.
T. any
manufacturers' recalls or conformance with manufacturer installation, or any
information included for consumer protection purposes.
U. operating
costs of systems.
V. replacement
or repair cost estimates.
W. the
acoustical properties of any systems.
X. estimates
of the cost to operate any given system.
II. The inspector is not
required to operate:
A. any
system that is shut down.
B. any
system that does not function properly.
C. or
evaluate low-voltage electrical systems such as, but not limited to:
1. phone lines;
2. cable lines;
3. satellite dishes;
4. antennae;
5. lights; or
6. remote controls.
D. any
system that does not turn on with the use of normal operating controls.
E. any
shut-off valves or manual stop valves.
F. any
electrical disconnect or over-current protection devices.
G. any
alarm systems.
H. moisture
meters, gas detectors or similar equipment.
III. The inspector is not
required to:
A. move any
personal items or other obstructions, such as, but not limited to:
1. throw
rugs;
2. furniture;
3. floor or
wall coverings;
4. ceiling
tiles;
5. window
coverings;
6. equipment;
7. plants;
8. ice;
9. debris;
10. snow;
11. water;
12. dirt;
13. foliage;
or
14. pets.
B. dismantle,
open or uncover any system or component.
C. enter or
access any area that may, in the opinion of the inspector, be unsafe.
D. enter
crawlspaces or other areas that are unsafe or not readily accessible.
E. inspect
underground items, such as, but not limited to, underground storage tanks or
other indications of their presence, whether abandoned or actively used.
F. do
anything which, in the inspector's opinion, is likely to be unsafe or dangerous
to the inspector or others, or damage property, such as, but not limited to:
walking on roof surfaces, climbing ladders, entering attic spaces, or
negotiating with pets.
G. inspect
decorative items.
H. inspect
common elements or areas in multi-unit housing.
I. inspect
intercoms, speaker systems, radio-controlled security devices, or lawn
irrigation systems.
J. offer
guarantees or warranties.
K. offer or
perform any engineering services.
L. offer or
perform any trade or professional service other than home inspection.
M. research
the history of the property, report on its potential for alteration,
modification, extendibility or suitability for a specific or proposed use for
occupancy.
N. determine
the age of construction or installation of any system structure or component of
a building, or differentiate between original construction and subsequent
additions, improvements, renovations or replacements.
O. determine
the insurability of a property.
P. perform
or offer Phase 1 environmental audits.
Q. inspect
any system or component which is not included in these Standards.
3.
Standards of Practice
3.1. Roof
I. The inspector shall inspect
from ground level or eaves:
A. the roof
covering/materials;
B. the
gutters;
C. the
downspouts;
D. the
vents, flashing, skylights, chimney and other roof penetrations; and
E. the
general structure of the roof from the readily accessible panels, doors or
stairs.
II. The inspector is not
required to:
A. walk on
any pitched roof surface.
B. predict
the service life expectancy.
C. inspect
underground downspout diverter drainage pipes.
D. remove
snow, ice, debris or other conditions that prohibit the observation of the roof
surfaces.
E. move
insulation.
F. inspect
antennae, satellite dishes, lightning arresters, de-icing equipment, or
similar attachments.
G. walk on
any roof areas that appear, in the opinion of the inspector, to be unsafe.
H. walk on
any roof areas if it might, in the opinion of the inspector, cause
damage.
I. perform
a water test.
J. warrant
or certify the roof.
K. confirm
proper fastening.
3.2. Exterior
I. The inspector shall inspect:
A. the
exterior wall-covering material, flashing and trim;
B. all
exterior doors, decks, stoops, steps, stairs, porches, railings, eaves, soffits
and fascias;
C. and
report as in need of repair any improper spacing between intermediate
balusters, spindles and rails for steps, stairways, balconies and
railings;
D. a
representative number of windows;
E. the
vegetation, surface drainage, and retaining walls when these are likely to
adversely affect the structure;
F. and
describe the exterior wall covering.
II. The inspector is not required
to:
A. inspect
or operate screens, storm windows, shutters, awnings, fences, outbuildings, or
exterior accent lighting.
B. inspect
items, including window and door flashing, that are not visible or readily
accessible from the ground.
C. inspect
geological, geotechnical, hydrological or soil conditions.
D. inspect
recreational facilities or playground equipment.
E. inspect
seawalls, breakwalls or docks.
F. inspect
erosion-control or earth-stabilization measures.
G. inspect
for safety-type glass.
H. inspect
underground utilities.
I. inspect
underground items.
J. inspect
wells or springs.
K. inspect
solar, wind or geothermal systems.
L. inspect
swimming pools or spas.
M. inspect
septic systems or cesspools.
N. inspect
sprinkler systems.
O. inspect
drainfields or dry wells.
P. determine
the integrity of the thermal window seals or damaged glass.
Q. inspect
any damaged glass.
3.3. Basement,
Foundation & Crawlspace
I. The inspector shall inspect:
A. the
basement;
B. the
foundation;
C. the
crawlspace;
D. the
visible structural components;
E. and
report on the location of under-floor access openings;
F. and
report any present conditions or clear indications of active water
penetration;
G. for wood
in contact with or near soil;
H. and
report any general indications of foundation movement, such as, but not limited
to: sheetrock cracks, brick cracks, out-of-square door frames, and floor
slopes;
I. and
report on any cutting, notching and boring of framing members that may
present a structural or safety concern.
II. The inspector is not
required to:
A. enter
any crawlspaces that are not readily accessible or where entry could cause
damage or pose a hazard to the inspector.
B. move
stored items or debris.
C. operate
sump pumps with inaccessible floats.
D. identify
size, spacing, span, location or determine adequacy of foundation bolting,
bracing, joists, joist spans or support systems.
E. provide
any engineering or architectural service.
F. report
on the adequacy of any structural system or component.
3.4. Heating
I. The inspector shall inspect:
A. the
heating systems, using normal operating controls, and describe the
energy source and heating method;
B. and
report as in need of repair heating systems that do not
operate;
C. and
report if the heating systems are deemed inaccessible.
II. The inspector is not
required to:
A. inspect
or evaluate the interior of flues or chimneys, fire chambers, heat
exchangers, combustion air systems, fresh air intakes, humidifiers,
dehumidifiers, electronic air filters, geothermal systems, or solar
heating systems.
B. inspect fuel
tanks or underground or concealed fuel supply systems.
C. determine
the uniformity, temperature, flow, balance, distribution, size, capacity, BTU,
or supply adequacy of the heating system.
D. light or
ignite pilot flames.
E. activate
heating, heat pump systems or other heating systems when ambient temperatures
or other circumstances are not conducive to safe operation or may damage the
equipment.
F. override
electronic thermostats.
G. evaluate
fuel quality.
H. verify
thermostat calibration, heat anticipation, or automatic setbacks, timers,
programs or clocks.
3.5. Cooling
I. The inspector shall inspect:
A. the
central cooling equipment using normal operating controls.
II. The inspector is not
required to:
A. determine
the uniformity, temperature, flow, balance, distribution, size, capacity, BTU,
or supply adequacy of the cooling system.
B. inspect
window units, through-wall units, or electronic air filters.
C. operate
equipment or systems if the exterior temperature is below 65° Fahrenheit,
or when other circumstances are not conducive to safe operation or may damage
the equipment.
D. inspect
or determine thermostat calibration, cooling anticipation, or automatic
setbacks or clocks.
E. examine
electrical current, coolant fluids or gases, or coolant leakage.
3.6. Plumbing
I. The inspector shall:
A. inspect
and determine whether the water supply is public or private;
B. verify
the presence and identify the location of the main water shut-off valve;
C. inspect
the water heating equipment, including venting, connections, energy
source supply system, and seismic bracing, and verify the presence or absence
of temperature-pressure relief valves and/or Watts 210 valves;
D. flush
toilets;
E. water-test
sinks, tubs and showers for functional drainage;
F. inspect
the interior water supply, including all fixtures and faucets;
G. inspect
the drain, waste and vent systems, including all fixtures;
H. describe any
visible fuel-storage systems;
I. inspect
the drainage sump pumps, and test pumps with accessible floats;
J. inspect
and describe the water supply, drain, waste and main fuel shut-off valves, as
well as the location of the water main and main fuel shut-off valves;
K. inspect
and report as in need of repair deficiencies in the water supply by viewing the
functional flow in two fixtures operated simultaneously;
L. inspect
and report as in need of repair deficiencies in installation and identification
of hot and cold water faucets;
M. inspect
and report as in need of repair any mechanical drain stops that are
missing or do not operate if installed in sinks, lavatories and tubs; and
N. inspect
and report as in need of repair commodes that have cracks in the ceramic
material, are improperly mounted on the floor, leak, or have tank
components that do not operate.
II. The inspector is not
required to:
A. light or
ignite pilot flames.
B. determine
the size, temperature, age, life expectancy or adequacy of the water
heater.
C. inspect
the interior of flues or chimneys, combustion air systems, water softener
or filtering systems, well pumps or tanks, safety or shut-off valves,
floor drains, lawn sprinkler systems, or fire sprinkler systems.
D. determine
the exact flow rate, volume, pressure, temperature or adequacy of the water
supply.
E. determine
the water quality, potability or reliability of the water supply or
source.
F. open
sealed plumbing access panels.
G. inspect
clothes washing machines or their connections.
H. operate
any main, branch or fixture valve.
I. test
shower pans, tub and shower surrounds or enclosures for leakage.
J. evaluate
the compliance with local or state conservation or energy standards, or the
proper design or sizing of any water, waste or venting components, fixtures or
piping.
K. determine
the effectiveness of anti-siphon, back-flow prevention or drain-stop
devices.
L. determine
whether there are sufficient cleanouts for effective cleaning of drains.
M. evaluate
gas, liquid propane or oil storage tanks.
N. inspect
any underground or concealed fuel supply systems.
O. inspect
any private sewage waste disposal system or component thereof.
P. inspect
water treatment systems or water filters.
Q. inspect
water storage tanks, pressure pumps or bladder tanks.
R. evaluate
wait-time to obtain hot water at fixtures, or perform testing of any kind to
water heater elements.
S. evaluate
or determine the adequacy of combustion air.
T. test,
operate, open or close safety controls, manual stop valves and/or
temperature or pressure-relief valves.
U. examine
ancillary systems or components, such as, but not limited to, those related to
solar water heating and hot water circulation.
V. determine
the existence or condition of polybutylene plumbing.
3.7. Electrical
I. The inspector shall inspect:
A. the
service drop/lateral;
B. the
meter socket enclosures;
C. the
means for disconnecting the service main;
D. and
describe the service disconnect amperage rating, if labeled;
E. panelboards
and over-current devices (breakers and fuses);
F. and
report on any unused circuit breaker panel openings that are not
filled;
G. the
service grounding and bonding;
H. a
representative number of switches, lighting fixtures and receptacles,
including receptacles observed and deemed to be arc-fault circuit interrupter
or AFCI-protected using the AFCI test button, where possible;
I. and test
all ground-fault circuit interrupter receptacles and circuit breakers observed
and deemed to be GFCIs using a GFCI tester, where possible;
J. and
report the presence of solid conductor aluminum branch circuit wiring, if
readily visible;
K. and
report on any tested receptacles in which power was not
present, polarity was incorrect, the cover was not in place, the GFCI
devices were not properly installed or did not operate
properly, evidence of arcing or excessive heat, and where the
receptacle was not grounded or was not secured to the wall;
L. the
service entrance conductors and the condition of the conductor
insulation;
M. and
report the absence of smoke detectors; and
N. service
entrance cables, and report as in need of repair deficiencies in the integrity
of the insulation, drip loop, or separation of conductors at weatherheads and
clearances from grade and rooftops.
II. The inspector is not
required to:
A. insert
any tool, probe or device into the main panelboard,
sub-panels, distribution panelboards, or electrical fixtures.
B. operate
electrical systems that are shut down.
C. remove
panelboard cabinet covers or dead fronts, if they are not readily
accessible.
D. operate
or re-set over-current protection devices or overload devices.
E. operate
non-accessible smoke detectors.
F. measure
or determine the amperage or voltage of the main service equipment, if not
visibly labeled.
G. inspect
the fire and alarm system or components.
H. inspect
the ancillary wiring or remote control devices.
I. activate
any electrical systems or branch circuits that are not energized.
J. inspect
low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any
time-controlled devices.
K. verify
the service ground.
L. inspect
private or emergency electrical supply sources, including, but not limited
to: generators, windmills, photovoltaic solar collectors, or battery or
electrical storage facility.
M. inspect
spark or lightning arrestors.
N. inspect
or test de-icing equipment.
O. conduct voltage-drop
calculations.
P. determine
the accuracy of labeling.
Q. inspect
exterior accent lighting.
3.8. Fireplace
I. The inspector shall inspect:
A. the
fireplace, and open and close the damper door, if readily accessible and
operable;
B. hearth
extensions and other permanently installed components;
C. and
report as in need of repair deficiencies in the lintel, hearth and material
surrounding the fireplace, including the fireplace opening's clearance from
visible combustible materials.
II. The inspector is not
required to:
A. inspect
the flue or vent system.
B. inspect
the interior of chimneys or flues, fire doors or screens, seals or
gaskets, or mantels.
C. determine
the need for a chimney sweep.
D. operate
gas fireplace inserts.
E. light
pilot flames.
F. determine
the appropriateness of any installation.
G. inspect
automatic fuel-feed devices.
H. inspect
combustion and/or make-up air devices.
I. inspect
heat-distribution assists, whether gravity-controlled or fan-assisted.
J. ignite
or extinguish fires.
K. determine
the adequacy of drafts or draft characteristics.
L. move
fireplace inserts, stoves or firebox contents.
M. perform
a smoke test.
N. dismantle
or remove any component.
O. perform
a National Fire Prevention Association (NFPA)-style inspection.
P. perform
a Phase I fireplace and chimney inspection.
3.9. Attic, Ventilation
& Insulation
I. The inspector shall inspect:
A. the
insulation in unfinished spaces;
B. for the
presence of attic ventilation;
C. mechanical
ventilation systems;
D. and
report on the general absence or lack of insulation in unfinished spaces.
II. The inspector is not
required to:
A. enter
the attic or any unfinished spaces that are not readily accessible, or where
entry could cause damage or pose a safety hazard to the inspector, in his or
her opinion.
B. move,
touch or disturb insulation.
C. move,
touch or disturb vapor retarders.
D. break or
otherwise damage the surface finish or weather seal on or around access
panels or covers.
E. identify
the composition or exact R-value of insulation material.
F. activate
thermostatically operated fans.
G. determine
the types of materials used in insulation or wrapping of pipes, ducts, jackets,
boilers or wiring.
H. determine
the adequacy of ventilation.
3.10. Doors, Windows
& Interior
I. The inspector shall:
A. open and
close a representative number of doors and windows;
B. inspect
the walls, ceilings, steps, stairways and railings;
C. and
report as in need of repair any improper spacing between intermediate
balusters, spindles and rails for steps, stairways and railings;
D. inspect
garage doors and garage door openers by operating first by remote (if
available) and then by the installed automatic door control;
E. and
report as improper any photoelectric safety sensor that fails to respond
adequately to testing;
F. and
report as in need of repair any door locks or side ropes that have not been
removed or disabled when the garage door opener is in use;
G. and
report as in need of repair any windows that are obviously fogged or display
other evidence of broken seals.
II. The inspector is not
required to:
A. inspect
paint, wallpaper, window treatments or finish treatments.
B. inspect
central vacuum systems.
C. inspect
safety glazing.
D. inspect
security systems or components.
E. evaluate
the fastening of countertops, cabinets, sink tops or fixtures.
F. move
furniture, stored items, or any coverings, such as carpets
or rugs, in order to inspect the concealed floor structure.
G. move
drop-ceiling tiles.
H. inspect
or move any household appliances.
I. inspect
or operate equipment housed in the garage, except as otherwise noted.
J. verify
or certify proper operation of any pressure-activated auto-reverse or related
safety feature of a garage door.
K. operate
or evaluate any security bar release and opening mechanisms, whether interior
or exterior, including their compliance with local, state or federal
standards.
L. operate any
system, appliance or component that requires the use of special keys, codes,
combinations or devices.
M. operate
or evaluate self-cleaning oven cycles, tilt guards/latches, or signal
lights.
N. inspect
microwave ovens or test leakage from microwave ovens.
O. operate
or examine any sauna, steam jenny, kiln, toaster, ice maker, coffee maker, can
opener, bread warmer, blender, instant hot-water dispenser, or other small,
ancillary devices.
P. inspect
elevators.
Q. inspect
remote controls.
R. inspect
appliances.
S. inspect
items not permanently installed.
T. discover
firewall compromises.
U. examine
or operate any above-ground, movable, freestanding, or otherwise
non-permanently installed pool, spa, recreational equipment or
self-contained equipment.
V. come
into contact with any pool or spa water in order to determine the system's
structure or components.
W. determine
the adequacy of spa jet water's force or bubble effect.
X. determine
the structural integrity or leakage of a pool or spa.
4.
Glossary of Terms
4.1. accessible: can
be approached or entered by the inspector safely, without difficulty, fear or
danger.
4.2. activate:
to turn on, supply power, or enable systems, equipment or devices to become
active by normal operating controls. Examples include turning on the gas or
water supply valves to the fixtures and appliances, and activating electrical
breakers or fuses.
4.3. adversely affect: to
constitute, or potentially constitute, a negative or destructive impact.
4.4. alarm system:
warning devices, installed or freestanding, including, but not limited to:
carbon monoxide detectors, flue gas and other spillage detectors, security
equipment, ejector pumps, and smoke alarms.
4.5. appliance:
a household device operated by the use of electricity or gas. Not included in
this definition are components covered under central heating, central cooling
or plumbing.
4.6. architectural
service: any practice involving the art and science of building
design for construction of any structure or grouping of structures, and the use
of space within and surrounding the structures or the design, design
development, preparation of construction contract documents, and administration
of the construction contract.
4.7. component:
a permanently installed or attached fixture, element or part of a system.
4.8. condition:
the visible and conspicuous state of being of an object.
4.9. crawlspace:
the area within the confines of the foundation and between the ground and the
underside of the lowest floor's structural component.
4.10. decorative: ornamental;
not required for the operation of essential systems or components of a
home.
4.11. describe:
to report in writing a system or component by its type or other observed
characteristics in order to distinguish it from other components used for the
same purpose.
4.12. determine:
to arrive at an opinion or conclusion pursuant to examination.
4.13. dismantle:
to open, take apart or remove any component, device or piece that would not
typically be opened, taken apart or removed by an ordinary occupant.
4.14. engineering
service: any professional service or creative work requiring
engineering education, training and experience, and the application of special
knowledge of the mathematical, physical and engineering sciences to such
professional service or creative work as consultation, investigation,
evaluation, planning, design and supervision of construction for the purpose of
assuring compliance with the specifications and design, in conjunction with
structures, buildings, machines, equipment, works or processes.
4.15. enter:
to go into an area to observe visible components.
4.16. evaluate:
to assess the systems, structures and/or components of a dwelling.
4.17. examine:
to visually look (see inspect).
4.18. foundation:
the base upon which the structure or wall rests; usually masonry, concrete or
stone, and generally partially underground.
4.19. function:
the action for which an item, component or system is specially fitted or used,
or for which an item, component or system exists; to be in action or perform a
task.
4.20. functional:
performing, or able to perform, a function.
4.21. home inspection:
the process by which an inspector visually examines the readily accessible
systems and components of a home and operates those systems and components
utilizing these Standards of Practice as a guideline.
4.22. household
appliances: kitchen and laundry appliances, room air conditioners,
and similar appliances.
4.23. inspect: to visually look at readily
accessible systems and components safely, using normal operating controls, and
accessing readily accessible panels and areas, in accordance with these
Standards of Practice.
4.24. inspected property: the readily accessible areas of the
buildings, site, items, components and systems included in the inspection.
4.25. inspector:
one who performs a real estate inspection.
4.26. installed:
attached or connected such that the installed item requires a tool for
removal.
4.27. material defect:
a condition of a residential real property or any portion of it that would
have a significant adverse impact on the value of the real property or that
involves an unreasonable risk to people on the property. The fact that a
structural element, system or subsystem is near, at or beyond the end
of its normal useful life is not, by itself, a material defect.
4.28. normal operating
controls: devices, such as thermostats, that would be operated by
ordinary occupants which require no specialized skill or knowledge.
4.29. observe:
to see through visually directed attention.
4.30. operate:
to cause systems to function or turn on with normal operating controls.
4.31. readily
accessible: an item or component that is, in the judgment of the
inspector, capable of being safely observed without the removal of obstacles,
detachment or disengagement of connecting or securing devices, or other unsafe
or difficult procedures to gain access.
4.32. recreational
facilities: spas, saunas, steam baths, swimming pools, tennis courts,
playground equipment, and other exercise, entertainment and athletic
facilities.
4.33. report:
a written communication (possibly including images) of any material
defects observed during the inspection.
4.34. representative
number: a sufficient number to serve as a typical or characteristic
example of the item(s) inspected.
4.35. safety glazing:
tempered glass, laminated glass, or rigid plastic.
4.36. shut down:
turned off, unplugged, inactive, not in service, not operational, etc.
4.37. structural
component: a component that supports non-variable forces or
weights (dead loads) and variable forces or weights (live loads).
4.38. system:
an assembly of various components which function as a whole.
4.39. technically
exhaustive: a comprehensive and detailed examination beyond the scope
of a real estate home inspection that would involve or include, but would
not be limited to: dismantling, specialized knowledge or training, special
equipment, measurements, calculations, testing, research, analysis, or other
means.
4.40. unsafe:
a condition in a system or component that is judged to be a significant
risk of personal injury during normal, day-to-day use. The risk may be due to
damage, deterioration, improper installation, or a change in accepted
residential construction standards.
4.41. verify:
to confirm or substantiate.
Shane Boyd,
Home Inspector
210 Kestrel Ct.
Myrtle Beach, SC 29588
(843) 458-1629
Email: buckeyehi@yahoo.com
|